INSTALLATION INSTRUCTIONS FOR MODEL 512 OIL LEVEL CONTROLLERS WITH ADAPTERS
Note: For fire safe oil level controllers (512-FS) see additional instructions in this work sheet covering installation of fire safe valves.
Figure 1- Side View of 512 I. SWITCH SPECIFICATIONS
II. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR OIL INLET VALVE:
Connect the oil supply line to the oil inlet on the oil level controller. The minimum recommended supply line is ¾” I.D. The supply
line must be clean and it is recommended that it be flushed with solvent before installation.
It is recommended that the oil supply line is connected using hose barb or tube fittings, using a reliable thread sealant. Do not use
Teflon tape.
Connect the oil supply line to the oil supply tank. If there is no existing valve at the tank or the existing supply outlet, a shut-off valve
should be placed in the line to prevent oil loss when cleaning the inlet screen or filter.
The oil inlet valve is adjusted to maintain the oil level at the center of the sight glass. Low or high levels are often caused by two
problems:
1. Excessive oil inlet pressure, which will cause the unit to overfill.
2. Improper equalizing lines between the crankcase and the controller will also result in improper levels.
Note: 512 models require a minimum of 2’ of head pressure and a maximum of 12’ of oil inlet head pressure.
III. INSTALLATION INSTRUCTIONS FOR UNITS WITH ADAPTERS:
OIL LEVEL CONTROLLERS WITH –1 (Clark MA & CFA) –2 (Clark HMB & TMB), -3 (Clark RA, HRA, HBA, HCA, HLA, TLA), -
6
(Cooper-Bessemer GMW), -7 (Cooper-Bessemer GMV), -8 (Cooper-Bessemer GMX), -16 , -16-R, -16-6.25 (Cooper-Bessemer BMV
& 275) AND FS OPTIONS
Remove the visual oil gauge assembly from the engine and replace it with the oil level controller and adapter assembly supplied with
a gasket and mounting bolts when applicable.
OIL LEVEL CONTROLLERS WITH
–4 (Ingersoll-Rand SVG & KVS), -5 (Ingersoll-Rand KVG) AND FS OPTIONS
Remove the visual oil gauge assembly from the engine and replace it with the oil level controller and adapter assembly supplied with
a gasket and mounting bolts.
If the visual oil gauge was vented back to the engine crankcase, remove the vent from the top of the adapter and tie it back to the
crankcase with tubing.
Note: It is important to ensure that there are no loops in this line for it must be trap free and self draining.
Switch Specifications: Case to Ground: 2 AMP, 30 VAC/VDC
Switch Adjustment:
Switch adjustment is not recommended.
Improper setting may result in damage to engine. Switch is
factory set at ½” drop. If adjustment for the application is
necessary, refer to figure 1 and follow these instructions:
Remove the cover of the condulet housing (A) by
unscrewing the 6 screws(B).
Rotate the slotted set screw(C) counter-clockwise to lower
the switch trip point 3/16”.
Rotate the slotted set screw(C) clockwise to raise the
switch trip point to a maximum of ½”.
Attach the wire from the controller to the low tension
terminal on the magneto.
NOTE: The switch is not factory adjusted for proper
shutdown level.
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 PHONE(918) 663-4406 FAX: (918) 663-4480 www.kenco-eng.com e-mail:[email protected]

Page 2 - Figure 3

OIL LEVEL CONTROLLERS WITH –9U (Universal adapter for 512 Oil Level Controllers), -12 (Pole mounted adapter) AND –FS OPTIONS • Set the controller so

Page 3 - 512-ML AND FS OPTIONS

OIL LEVEL CONTROLLER WITH –17 (Waukesha VHP Engines F2895, F3251, F5108, L5790 & L7042), -18 (-17 w/ meter), -27 (for newer Waukesha engines s

Page 4 - Figure 5- 512-Ajax

OIL LEVEL CONTROLLER MODEL 512-SML AND FS OPTIONS • Remove the four screws on the end of the lubricator with the filler cap • Bolt the control

Page 5

IV. INSTALLATION INSTRUCTIONS FOR FIRE SAFE VALVES (Patent No. 3,877,476): See Figure 7 NOTE: All lines between thermal valves, the supply tanks an