Kenco-engineering KEFS User Manual

Browse online or download User Manual for Sensors Kenco-engineering KEFS. Kenco Engineering KEFS User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
KENCO ENGINEERING COMPANY
P.O. BOX 470426 TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4406
www.kenco-eng.com e-mail: [email protected]
MODEL KEFS LIQUID LEVEL FLOAT SWITCH
INSTALLATION / OPERATION INSTRUCTIONS
PRINCIPLE OF OPERATION
The Model KEFS uses a float to determine the presence or absence of liquid at the process connection. The float arm assembly
consists of a float at one end and a magnet at the other. As the level rises, the float rises, and the magnet falls. The magnet
actuates a second magnet on the other side of the pressure boundary. This second magnet causes the switch to change state.
The pressure boundary contains no seals; it is a solid stainless steel barrier that passes a magnetic field, but no liquids. It is
impossible for the process liquid to enter the switch enclosure through this barrier.
The electrical contacts consist of a microswitch that can be either a Single-pole, Double-throw (SPDT) or Double-pole, Double-throw
(DPDT) Configuration. The SPDT Switch is available with either a 5 Amp or 8 Amp current load. The DPDT is available with a 5
Amp/30Vdc current load (See Switch Types and Ratings in the Product Specifications for more details).
MODEL DESCRIPTION
KEFS - - - -
Process Connection
Switch Rating
Temperature Rating
Wetted Parts
* High
temperature option only available with 5A SPDT switch
(58639 Rev B)
Temperature Rating Wetted Parts
Description Code Description Code
Standard
blank
303 SS (std.)
blank
High* 400 316 SS S6
Process Connection Switch Rating
Description Code Description Code
1½” NPT N/A 5A SPDT SPDT5
2” NPT (std.) 2 4A DPDT DPDT4
8A SPDT SPDT8
Page view 0
1 2 3 4

Summary of Contents

Page 1 - KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 ● PHONE: (918) 663-4406 FAX: (918) 663-4406 www.kenco-eng.com e-mail: info@kenco-eng.

Page 2

SWITCH DIMENSIONS INSTALLATION Unpack the switch carefully. Inspect the unit(s) for damage. Report any damage to carrier immediately. Check the

Page 3

WIRING TERMINALS CM = Common; NC = Normally Closed; NO=Normally Open 1 = Used in both SPDT and DPDT Switches; 2 = Used in DPDT Switches Only 1.

Page 4

8. Carefully reinstall the Switch Housing Cover; BE CAREFUL not to pinch the wires PRODUCT SPECIFICATIONS Description Specification Spec

Comments to this Manuals